Open Microfluidics home page

Animations home page

Figure 3-41

This browser does not support the necessary features to display this graphic. Downloading 0% completee

Liquid entering a shallow circular chamber.

The contact angle on all surfaces is 25 degrees, so Concus-Finn filaments can form. On entering the chamber, the filament continue along the sides until joining at the far end. The liquid does not fill the chamber, but forms a nearly-catenoid surface that makes the proper contact angle with the floor.