Open Microfluidics home page

Animations home page

Figure6-34

This browser does not support the necessary features to display this graphic. Downloading 0% completee

Liquid between rails with three pillars between the rails.

The contact angle on the lower rail and pillars is 50 degrees, and the contact angle with the top rail is 120 degrees. The liquid gets around the pillars on the bottom, but not the top, and the advance stops.